Rotary Bundle-imaging Fluorescence Mini Cubes Gen.2 - System
Rotary Bundle-imaging Fluorescence Mini Cubes Gen.2 - System
Rotary Bundle-imaging fiber photometry (RBFMC-G2) is an elegant alternative for long-term, multiple-site recordings in freely-moving animals. This CMOS-based photometry system is fixed onto the motorized rotary joint, allowing signal detection during the rotation. This design completely abolishes rotation artifacts and is ideal for recording subtle signals from sparse neural populations and/or from axons.
Rotary Bundle-imaging fiber photometry (RBFMC-G2) is an elegant alternative for long-term, multiple-site recordings in freely-moving animals. This CMOS-based photometry system is fixed onto the motorized rotary joint, allowing signal detection during the rotation. This design completely abolishes rotation artifacts and is ideal for recording subtle signals from sparse neural populations and/or from axons.
Both Fan-out and High-density bundle patch cords are interchangeably compatible with the Sample port of the same RBFMC-G2. The Fan-out option is designed for multiple distant brain regions, each fitted with Mono Fiber-optic cannula, while the High-density type is designed for High-density cannulas
RBFMC-G2 configurations:- Two-color photometry (Green & Red + isosbestic)
- One-color photometry (Green + isosbestic) with red-shifted optogenetics (a single red LED (wavelength) illuminates all the photometry sites, simultaneously)
Note: it is possible to swap between the two configurations by changing the optical mini cube connected to the rotary joint.
In addition, both RBFMC-G2 configurations are compatible with an additional optogenetic site. This option mounts a laser (one of 6 wavelength options) on the outside of the optical cube for optogenetic stimulation on non-photometry sites.
RBFMC-G2 also has an HDMI port to record electrophysiological signals from the animal with Doric's electrophysiology consoles (EPC, NC500). It is also possible to purchase an adaptor for common electrophysiology systems (Intan, Neuropixel, etc.). Thus, with this state-of-the-art system, users can simultaneously record multi-site photometry, optogenetics, and electrophysiology signals from the same, freely-moving animal.
The GCaMP with Red Fluorophore Rotary Bundle-imaging Fiber Photometry System Gen.2 contains all items necessary to perform fiber photometry measurements on many sites with GFP-like fluorophores. It also measures the isosbestic excitation of GCaMP fluorescence and collects the red fluorescence on the same sensor. The fluorescence resulting from different excitations are demodulated by sequential acquisition.
The system includes:
- Behavior & Bundle Photometry Console (BBC300) or NC500
- Rotary Bundle-imaging Fluorescence Mini Cubes Gen.2 - Rotary joint
- Rotary Bundle-imaging Fluorescence Mini Cubes Gen.2 - Cube GCaMP + RFP
- Isosbestic LED for exchangeable isosbestic point (404, 415, 425 and 440 nm)
- All required electrical cables and patch cords
Optional items:
- Isosbestic LED (ILED) to swap the isosbestic excitation on the RBFMC
- Connectorized Laser Diode Modules to add an external optogenetic light source
- Fiber Photometry Cannula Holder to record during surgery
- Optical Power meter to monitor and calibrate excitation power
- Behavior Camera or CamLoop to record animal behavior
- Workstation
- danse™ analyzing software
Accessories:
- Low-autofluorescence Branching Fiber Patch cords to bring light to the animal
- High-density Fiber-optic cannula and patch cord for multiple fibers with high placing precision chronic implant
- Fiber-optic Cannulas for chronic implant
- Mating sleeves for ferrule to ferrule interconnect

The GCaMP with Red Opto Rotary Bundle-imaging Fiber Photometry System contains all items necessary to perform fiber photometry measurements on many sites with GFP-like fluorophores and optogenetics stimulation of red shifted opsins in the same sites.
The system includes:
- Behavior & Bundle Photometry Console (BBC300) or Neuroscience Console (NC500)
- Rotary Bundle-imaging Fluorescence Mini Cubes Gen.2 - Rotary joint
- Rotary Bundle-imaging Fluorescence Mini Cubes Gen.2 - Cube GCaMP + Red Opto
- Isosbestic LED for exchangeable isosbestic point (404, 415, 425 and 440 nm)
- All required electrical cables and patch cords
Optional items
- Isosbestic LED (ILED) to swap the isosbestic excitation on the RBFMC
- Connectorized Laser Diode Modules to add an external optogenetic light source
- Fiber Photometry Cannula Holder to record during surgery
- Optical Power meter to monitor and calibrate excitation power
- Behavior Camera or CamLoop to record animal behavior
- Workstation
- danse™ analyzing software
Accessories:
- Low-autofluorescence Branching Fiber Patch cords to bring light to the animal
- High-density Fiber-optic cannula and patch cord for multiple fibers with high placing precision chronic implant
- Fiber-optic Cannulas for chronic implant
- Mating sleeves for ferrule to ferrule interconnect

The External optogenetics option fixes a small Laser diode module (CLDM) onto the rotor portion of the RBFMC, providing an additional optogenetic-only stimulation. Both the 2-color (GCaMP + RFP) and the 1-color (GCaMP + Red Opto) configurations are compatible with the external optogenetics
The integrated laser driver inside the RBFMC-G2 (E4 port) controls the timing and intensity independent to the internal fiber photometry/optogenetics.
All six wavelengths of the Laser diode module (CLDM) can be used with the RBFMC-G2. However, we strongly recommend using the 638nm laser, as it works well with ChrimsonR opsin.

External Optogenetic items:
- Connectorized Laser Diode Modules (for RBFMC) to add an external optogenetic light source (includes holder to fix rotary joint in place)
Accessories
- Fiber Patch cords to bring laser light to the animal
- Splitting-branching Fiber Patch Cords to split the laser light into 2+ fibers going to the animal
- Fiber-optic Cannulas for chronic implant
- Mating sleeves for ferrule to ferrule interconnect

This is the only rotary joint solution for simultaneous, multi-site (3+) fiber photometry and electrical recordings. The RBFMC-G2 comes, by default, with two electrical connectors that support electrophysiology(up to 12 pins) or EGG/EMG. The ports can also be used to add custom electrical components (IMU, etc.).
The RBFMC-G2 is designed to work with the NC500 for simultaneous bundle-imaging and electrophysiology recordings. This solution provides a single interface to record both signal types in perfect synchronization. The NC500 system uses either 16-channel or 32-channel Intan RDH headstages and is compatible with Doric multi-electrode optoelectric cannulas (OEC-Multi), with up to 18 pins.
Note that the connector types on the RBFMC are different, depending on their location
- Rotor Side: PZN12
- Stator Side: HDMI
*Adaptors available for compatibility with non-Doric electrophysiology system
Doric Electrophysiology system items
- NC500
- Adaptors HDMI-HDMI Stator side (RBFMC -> NC500)
- Adaptors PZN12-PZN12 Rotor side (RBFMC -> animal)
- Optoelectric Cannula (OEC-Multi) Multi-electrode cannula implant, one optic fiber with up to 12 pins
Intan Electrophysiology
- Adaptors HDMI-PZN12 Stator side (RBFMC -> acquisition system)
- Adaptors PZN12-PZN12 Rotor side (RBFMC -> animal)
Neuropixel Electrophysiology adaptors
- Adaptors HDMI-USBC Stator side (RBFMC -> acquisition system)
- Adaptors NPX-PZN12 Rotor side (RBFMC -> animal)


| GCaMP + RFP | GCaMP + Red Opto | |
| Wavelength range | 350 to 1100 nm | |
| Field of view | Ø1.30 mm | |
| Objective NA | 0.50 | |
| Maximum number of sites * could be limited by patchcord manufacturing | - 7x core 400 µm NA0.57 - 20x core 200 µm NA0.57 - 90x core 100 µm NA0.37 | |
| Excitation Uniformity | 10% over FOV | |
| Optical fiber compatibility | - Core diameter 100, 200, or 400 µm | |
| Spectral bandwidth | - Excitation #1 : 405-410 or 410-415 nm or 421-433 nm or 433-445 nm - Excitation #2 : 460-490 nm - Excitation #3 : 555-570 nm - Emission #1 : 500-550 nm - Emission #2 : 580-680n | - Excitation #1 : 405-410 or 410-415 nm or 421-433 nm or 433-445 nm - Excitation #2 : 460-490 nm - Excitation #3 : 580-650 nm - Emission #1 : 500-540 nm |
| Optical filter attenuation | > OD 5 outside band | |
| Optical fiber connector | SMA | |
| Dimensions | 102 mm x 102 mm x 346mm | |
| SENSOR | ||
| Type | CMOS Image sensor | |
| Resolution | 540x 540 px | |
| Pixel Size | 6.9µm x6.9 µm | |
| Frame rate | up to 125 Hz (1 & 2 excitations) up to 60 Hz (3 excitations) | |
| Computer interface | USB 3.0 | |
| Build-in LEDs | ||
| Max Current | 500 mA (LED 400-410 nm or 410-415 nm or 421-433 nm or 433-445 nm, LED 460-490 nm) | |
| 1000 mA (LED 555-570 nm) | 1000 mA (LED Opto 600-640 nm) | |
| Max Output Power (400 µm fiber, NA 0.57) | LED 400-410 nm or 410-415 nm = 60µW (at 200 mA, CW) | |
| LED 460-490 nm = 230 µW (at 200 mA, CW) | ||
| LED 555-570 nm = 150 µW (at 200 mA, CW) | LED Opto 600-640 nm = 7 mW (at 1000 mA, CW) | |
| Additional Optogenetic site | ||
| Connector | M8 | |
| Max Current | 1000 mA | |
| Electrophysiology | ||
| Connector | PZN12 (rotor) HDMI (stator) | |