Skip to content
Cart

The Bundle-imaging Fiber Photometry Cube with Targeted Optogenetics (BFTO) enables multi-site measurements through High-density Fiber-optic Patch Cords (HDP). These patch cords are available in either square or hexagonal patterns of 7, 9 or 19 fibers connected to the sample port, allowing combined optogenetics and photometry recording.


Build-in LEDs combine Isosbestic & Functional GCaMP excitations with Red Fluorophore excitation. Isosbestic and functional fluorescent signals are recorded with the same image sensor by interleaving the excitations. Both the LED driver and the CMOS detector are integrated within the system. The optogenetics stimulation pattern can vary in type, number and emitted wavelengths. For this purpose, a second similar high-density fiber optic patch cord is connected to the optogenetic port and fans out into separate connectors. Then, up to 19 independent optogenetic stimulation inputs can be connected depending on the needs of the experiment (one input per fiber connected to the sample port).
The BFTO system with targeted optogenetics supports the following fluorophore and opsin combinations:

 


Fluorophores

Green Fluorophore 
(GCAMP, dLight)

Exc 460-490nm / Em 500-540nm

Red Fluorophore
(RCAMP, Jrgeco1A, dTomato)

Exc 555-570nm / Em 580-600nm

Opsins

ChR2
450 nm

N/A

Sequential

NpHR/Chrimson
Jaws
638 nm*

Simultaneous or Sequential

Simultaneous or Sequential


*560/590 on request


    Wavelength range350 to 1100 nm
    Field of viewØ3 mm
    Objective NA0.40
    Maximum number of sites*
    - 7x core 400 µm NA0.37
    - 9x core 400 µm NA0.37
    - 19x core 200 µm NA0.37
    LEDs Excitation Uniformity80% over FOV
    Optogenetics Excitation Uniformity65% over FOV
    Optogenetics Crosstalk between fibers>31 dB
    Optical fiber compatibility- Core diameter 200, or 400 µm
    - NA 0.37
    Spectral bandwidth- Excitation #1 : 405-410 or 410-415 nm
    - Excitation #2 : 460-490 nm
    - Excitation #3 : 555-570 nm
    - Emission #1 : 500-540 nm
    - Emission #2 : 580-600 nm
    Optical filter attenuation> OD 5 outside band
    Optical fiber connectorHD7, HD9 or HD19
    Dimensions220mm x 220mm x 59mm
    SENSOR
    TypeCMOS image sensor
    Resolution1024x1024 px
    Pixel size5.86 µm x 5.86 µm
    Frame rateup to 60 Hz
    Computer interfaceUSB 3.0
    * could be limited by patchcord manufacturing
    Drawing

    Bundle-imaging Fiber Photometry Cube with Targeted Optogenetics

    User ManualFREN

    Bundle-imaging Fiber Photometry Cube with Targeted Optogenetics

    The Bundle-imaging Fiber Photometry with Targeted Optogenetics System contains all items necessary to perform fiber photometry measurements on a large number of sites with green or red fluorophores on the same detector. It also features an optical fiber input port to connect to red or blue opsin activation or inhibition light source.

    The system includes:

    Optional items:


    Accessories:

    Item added to cart