{"title":"Fiber Photometry Systems","description":"\u003cp\u003eEach system differs in terms of \u003cspan\u003echannel configuration, maximum number of site\/animal(s), dual-color \u0026amp; optogenetics compatibility, and advanced features across seven distinct fiber photometry systems. \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003ebasic system\u003c\/strong\u003e \u003cimg height=\"18\" width=\"18\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Tags_icons_FMC_92px.png?v=1771010344\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Tags_icons_RFMC_92px.png?v=1771010344\" alt=\"\" width=\"19\" height=\"19\"\u003e is the original, photodetector-based technology with decade-long validation. \u003c\/span\u003e\u003cspan\u003eThe \u003cstrong\u003ebundle-imaging systems\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Tags_icons_BFMC_92px.png?v=1771010345\" alt=\"\" width=\"18\" height=\"18\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Tags_icons_BFTO_92px.png?v=1771010344\" alt=\"\" width=\"19\" height=\"19\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Tags_icons_RBFMC_92px.png?v=1771010344\" alt=\"\" width=\"22\" height=\"22\"\u003e use CMOS sensor(s) to record multiple fibers simultaneously. \u003c\/span\u003e\u003cspan\u003eThe \u003cstrong\u003erotary-integrated systems\u003c\/strong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Tags_icons_RFMC_92px.png?v=1771010344\" alt=\"\" width=\"19\" height=\"19\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Tags_icons_RBFMC_92px.png?v=1771010344\" alt=\"\" width=\"22\" height=\"22\"\u003e built-in mini cube (optics, LED, and detector) on the rotary joint, such that the detector turns with the animal, completely abolishing rotation-related artifacts. \u003c\/span\u003e\u003cspan\u003eThe \u003cstrong\u003ewireless system\u003c\/strong\u003e \u003cimg height=\"21\" width=\"21\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Tags_icons_WIFP_92px.png?v=1771010344\"\u003e is a cable-free solution that supports multiple interacting animals. \u003c\/span\u003e\u003cspan\u003eThe \u003cstrong\u003efluorescence lifetime system\u003c\/strong\u003e \u003cimg height=\"22\" width=\"22\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Tags_icons_FLUOPULSE_92px.png?v=1771010344\"\u003e measures picosecond changes in lifetime and is ideal to measure tonic\/baseline changes over long periods of time. Click this link for a \u003cspan style=\"color: rgb(17, 5, 250);\"\u003e\u003ca style=\"color: rgb(17, 5, 250);\" href=\"https:\/\/neuro.doriclenses.com\/pages\/fp-solution-page\"\u003ecomparison of all fiber photometry systems\u003c\/a\u003e\u003c\/span\u003e.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"wifp","title":"Wireless Fiber Photometry System","description":"\u003cp\u003eWireless Fiber Photometry System provides a \u003cstrong\u003ecable-free solution\u003c\/strong\u003e for fiber photometry experiments in freely-moving animals. This solution supports up to four wireless headstages simultaneously, enabling records from multiple animals in the same cage. This system is ideal for those studying\u003cstrong\u003e neural populations underlying social behaviors\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":47933644964082,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Wireless_system_b2fe41d4-1164-43db-b460-0e2f4b132cb7.png?v=1769715073"},{"product_id":"fluopulse","title":"FluoPulse™ System","description":"\u003cp\u003eFluoPulse™ system is the first commercial, plug-and-play Fluorescence Lifetime Fiber Photometry (FLiP) system available on the market, designed for neuroscience. This system measures changes in a biosensor's fluorescence lifetime, and is an essential tool to monitor intracellular biochemical reactions in the brains of freely moving animals.\u003c\/p\u003e\n\u003cp\u003eThe term \"fluorescence lifetime\" denotes the time lapse between the laser excitation and the release of fluorescence by the biosensor. Specially designed biosensors have unique lifetime distributions depending on whether they are in bound or unbound states. This disparity can be leveraged to study changes in neurophysiological states of key neural populations, including protein-protein interactions, changes in protein conformation, and the presence of neurotransmitters or other molecules of interest.\u003c\/p\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":47933645422834,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Fluopulse_system_0ae98b74-7299-4c35-bc22-daf2bfe3a768.png?v=1769715561"},{"product_id":"rbfmc-g2","title":"Rotary Bundle-imaging Fluorescence Mini Cubes Gen.2 - System","description":"\u003cp\u003e\u003cem\u003eRotary Bundle-imaging fiber photometry (RBFMC-G2) \u003c\/em\u003eis an elegant alternative for \u003cstrong\u003elong-term, multiple-site\u003c\/strong\u003e recordings in \u003cstrong\u003efreely-moving animals\u003c\/strong\u003e. This CMOS-based photometry system is fixed onto the motorized rotary joint, \u003cstrong\u003eallowing signal detection during the rotation\u003c\/strong\u003e. This design completely \u003cstrong\u003eabolishes rotation artifacts \u003c\/strong\u003eand is ideal for recording \u003cstrong\u003esubtle signals \u003c\/strong\u003efrom sparse neural populations and\/or from axons.\u003c\/p\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":47933645521138,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Rotary_Bundle-imaging_Fluorescence_Mini_Cubes_Gen2_System_ef29d18d-f3ef-4314-af6a-5981819b1da0.png?v=1769715431"},{"product_id":"bundle-imaging-fluorescence-photometry-system-gen-3","title":"Bundle-imaging Fiber Photometry System (integrated)","description":"\u003cp\u003e\u003cspan\u003eDoric's Bundle-imaging Fiber Photometry System (BFMC) is fully integrated, offering a hassle-free, plug-and-play solution. To record green and red photometry signals, the BFMC uses built-in LEDs to illuminate the entire sample port, and a CMOS sensor to simultaneously image the fluorescent signal from every fiber within the bundle. The fluorescent light collected from each fiber within the bundle creates circular spots on a CMOS sensor. The electrical read-out from pixels within each fiber image correlates with the calcium activity of the corresponding brain site. \u003cbr\u003e\u003cbr\u003eThe BFMC system is equipped with 8 Digital Input\/Output (DIO) ports and a DB25 adapter for synchronization and closed-loop experiments with external devices such as behavior cameras, operant conditioning chambers, video tracking software, and optogenetic light sources.\u003cbr\u003e\u003cbr\u003eTo combine \u003cstrong\u003ebundle photometry\u003c\/strong\u003e with \u003cstrong\u003eoptogenetics\u003c\/strong\u003e see Doric \u003ca title=\"Bundle Fiber Photometry with Targetted Optogenetics\" href=\"https:\/\/doric-neuro.myshopify.com\/products\/bfto-system\" target=\"_blank\" rel=\"noopener\"\u003eBFTO systems\u003c\/a\u003e.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":47933645848818,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Bundle_imaging_fiber_photometry_system_integrated_7a4c61a6-f738-4754-bcb0-492c34594f9c.png?v=1769715291"},{"product_id":"bfto-system","title":"Bundle-imaging Fiber Photometry with Targeted Optogenetics System","description":"\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe \u003c\/span\u003eBundle-imaging Fiber Photometry Cube with Targeted Optogenetics \u003cspan data-mce-fragment=\"1\"\u003e(BFTO) enables multi-site measurements through High-density Fiber-optic Patch Cords \u003c\/span\u003e(\u003ca href=\"https:\/\/neuro.doriclenses.com\/\/products\/high-density-fiber-optic-patch-cords?\"\u003eHDP\u003c\/a\u003e). These patch cords are available in either square or hexagonal patterns of 7, 9 or 19 fibers connected to the sample port, allowing combined optogenetics and photometry recording.\u003c\/p\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":47933646700786,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Bundle_imaging_fiber_photometry_with_targeted_optogenetic_system_5cc9c059-c4de-44f0-bef3-0e192e2d7243.png?v=1769715380"},{"product_id":"rotary-fiber-photometry-system","title":"Rotary Fiber Photometry System","description":"\u003cp\u003eRecording fluorescence related to neuronal activity within the brains of freely moving tethered laboratory animals is often hindered by transmission losses and signal fluctuations resulting from rotary joint turns. To mitigate these challenges, we strategically position the Fluorescence Mini Cube with integrated LEDs and detectors at the bottom of a rotating part of a 24-channel Assisted Electrical Rotary Joint. This placement allows us to enhance overall optical transmission and effectively eliminate rotation-related artifacts.\u003c\/p\u003e\n\u003cp\u003eMoreover, the rotary joint features a central hole or lumen, facilitating the passage of an optical fiber for optogenetic stimulation and\/or a tube for liquid delivery.\u003c\/p\u003e\n\u003cp\u003eThe Rotary Fiber Photometry System is highly adaptable. It can be tailored to support alternative light sources, such as laser diodes, and accommodate various fluorophores, ensuring versatility for different experimental setups.\u003c\/p\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":47933653811442,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Rotary_basic_system_838cbcd5-f7cc-4f91-b3ef-2cf616d31846.png?v=1769715265"},{"product_id":"fiber-photometry-system-basic","title":"Basic Fiber Photometry System","description":"\u003cp\u003eThe conventional fiber photometry systems for behaving animals consist of Fiber Photometry Console (FPC), an integrated Fluorescence Mini Cube (FMC), Pigtailed 1x1 Fiber-optic Rotary Joint (FRJ_1x1_pt), and Mono Fiber-optic Cannula (MFC). The fiber-optic rotary joint transfers the light signals and allows fiber tether rotation. Currently, we offer LED light sources for GCaMP (or other green fluorophores), GCaMP with Red Fluo, and FRET(CFP\/YFP). Explore the possibility of customization with other light sources, fluorophores, or assisted rotary joint.\u003cbr\u003e\u003c\/p\u003e\n","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":47933653844210,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Basic_system_c8028e54-9244-4b85-addf-cd81ba4f20f0.png?v=1769715127"},{"product_id":"bundle-imaging-fiber-photometry-system","title":"Bundle-imaging Fiber Photometry System (modular)","description":"\u003cp\u003eConventional photodiode-based fiber photometry recordings of multiple brain sites on the same animal or single sites on several animals require a recording setup for each fiber location.\u003c\/p\u003e\n\u003cp\u003eAn elegant alternative to multiple site photodiode-based fiber photometry is CMOS- or sCMOS-based bundle-imaging fiber photometry. The setup resembles a fluorescence microscope with a fiber bundle end face in its focal plane. The individual fibers on the other end of the fiber bundle are fitted to the selected brain locations on a single animal or on different animals. The fluorescent light from each fiber within a bundle creates circular spots on CMOS. The electrical read-out from pixels within each of those spots or fiber images correlates with the calcium activity of the corresponding brain site.\u003c\/p\u003e","brand":"Doric Lenses Inc.","offers":[{"title":"Default Title","offer_id":47933653876978,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0771\/1916\/0562\/files\/Bundle_imaging_fiber_photometry_system_modular_efe55683-deb1-4e7b-9c24-22c8786f4a68.png?v=1769715347"}],"url":"https:\/\/neuro.doriclenses.com\/fr\/collections\/fiber-photometry-systems.oembed","provider":"Doric Lenses","version":"1.0","type":"link"}